MTU C23R Istruzioni per gli Interventi Pagina 68

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
Vedere la pagina 67
Fault code No. Full designation Meaning Action
Related
parameter
No.
245 SD ECU Supply Voltage
Sensor fault (ECU operating
voltage). Replace ECU. 2.8006589
266 SD Speed Setting External speed setting faulty.
1. Check cabling.
2. Check speed set-
ting.
2.8006.58
6
269 SD Loadp. Analog Filt.
SD alarm configuration; Fil-
tered analog signal of load
pulse missing; short circuit
or wire break.
Check cabling, re-
place as necessary.
Error cleared after
restarting the en-
gine.
2.8006.58
8
270 SD Frequency Input
Frequency setting sensor
faulty.
1. Check cabling.
2. Contact Service.;
Check setpoint
speed transmitter.
2.8006.59
0
301
TIMING CYLINDER(A1-
A10)
Timing bank 1 (solenoid
valve 1) ... Timing bank 1
(solenoid valve 10)
Replace injector
concerned if the
fault message ap-
pears frequently
(→ Page 97).
1.8004.50
0
302 - - -
1.8004.50
1
303 - - -
1.8004.50
2
304 - - -
1.8004.50
3
305 - - -
1.8004.50
4
306 - - -
1.8004.50
5
307 - - -
1.8004.50
6
308 - - -
1.8004.50
7
309 - - -
1.8004.50
8
310 - - -
1.8004.50
9
311
TIMING CYLINDER(B1-
B10)
Timing Bank 2 (solenoid
valve 1) ... Timing Bank 2
(solenoid valve 10)
Replace injector
concerned if the
fault message ap-
pears frequently
(→ Page 97).
1.8004.51
0
312 - - -
1.8004.51
1
313 - - -
1.8004.51
2
314 - - -
1.8004.51
3
68 | Troubleshooting | M015695/03E 2013-03
TIM-ID: 0000033662 - 001